ASTM A500 ERW steel pipe

Date:2023-04-12View:481Tags:ASTM A500 ERW steel pipe,ERW steel pipe,ASTM specification A500

Specifications for ERW steel pipe---ASTM A500

All our structural tubes are produced in accordance with the mechanical and chemical property requirements of ASTM specification A500, Grade A, B, C.

ASTM A500 ERW steel pipe Mechanical Properties

Properties

Grade A

Grade B

Grade C

Tensile Strength, min. psi

45,000 (310Mpa)

58,000 (400Mpa)

62,000 (427Mpa)

Yield Strength, min. psi

39,000 (269Mpa)

46,000 (317Mpa)

50,000 (345Mpa)

Elongation in 2” min.
3/16” wall & heavier
1/8” wall

25%

25%

23%

19.5%

21%

21%







ASTM A500 ERW steel pipe Outside Dimensions

Largest Outside Dimension

Tolerance*

2-1/2” and under

±0.020”

Over 2-1/2” to 3-1/2” inclusive

±0.025”

Over 3-1/2” to 5-1/2” inclusive

±0.030”

Over 5-1/2”

±1%

*Tolerances include allowance for convexity or concavity. For rectangular tubing having a ratio of outside large to small flat dimension less than 1.5, and for square tubing, the tolerance on small flat dimension shall be identical to the large flat dimension tolerance. For rectangular tubing having a ratio of outside large to small flat dimension in the range of 1.5 to 3.0 inclusive, the tolerance on small flat dimension shall be 1.5 times the large flat dimension tolerance. For rectangular tubing having a ratio of outside large to small flat dimension greater than 3.0, the tolerance on small flat dimension shall be 2.0 times the large flat dimension tolerance.

Chemical Composition

Twist




Chemical

Grades A&B

Grade C

Largest Side

Maximum Twist in 3 feet

Carbon, max. %

0.26

0.23

Over 1-1/2” to 2-1/2” inclusive

.062”

Manganese, max. %

---

1.35

Over 2-1/2” to 4” inclusive

.075”

Phosphorus, max. %

0.04

0.04

Over 4” to 6” inclusive

.087”

Sulphur, max. %

0.05

0.05

Over 6” to 8” inclusive

.100”

Cooper, when cooper steel is specified min. %

0.20

0.20

Over 8”

.112”






Straightness: .025” times the number of feet of total length
Squareness of Sides: Deviation from 90ce by +/-2ce max.

Radius of Corners: The radius of any outside corner shall not exceed three times the specified wall thickness.

Wall thickness: +/-10% of nominal wall thickness, as measured at the center of the flat.

Remarks: a).1’ = 0.3048m, 1” = 25.4mm

b).1PSI = 0.00689Mpa